GENESIS Split Ducted
Commercial Comfort, Designed Around Flexibility
Reliable Comfort, Designed for Demanding Commercial Spaces
The ActronAir GENESIS Split Ducted Series is designed to deliver reliable, efficient comfort for large commercial spaces where performance, flexibility and serviceability matter. Built around R32 refrigerant, the range combines inverter driven performance, practical installation flexibility and commercial control options to support modern building requirements.
Suited to offices, schools, retail environments, warehouses and larger commercial facilities, GENESIS Split Ducted supports both new projects and retrofit applications where existing ductwork, plantroom access or site constraints need to be considered.
Capacities:
3 Phase
72.0kW, 85.0kW, 96.0kW
Compressor:
Inverter Scroll Compressor
Operating Range:
From -15ºC up to 57ºC
Product Features
Low GWP R32
Inverter Scroll
Compressor
ECM Variable
Speed Fans
Energy
Efficient
Installation
Flexibility
Adaptive
Defrost Logic
Louvered
Grille Guard
Commissioning
Tool (BCT)
Consistent, Efficient Performance
Advanced Technology
A considered selection of components, including R32 inverter scroll compressors, VSD drives and EC plug fans, helps GENESIS Split Ducted deliver precise system control, improved operating efficiency and quieter performance.
The system is designed to adapt to changing cooling and heating demands, supporting stable comfort without relying on constant full-load operation.
Intuitive Controls
GENESIS offers a wide range of control options to support precise comfort management across commercial applications. This includes our award-winning NEO with an intuitive interface and smart dashboards, supported by a broader controls range including Group Controller and LC7 for functions such as after-hours operation and Modbus BMS connectivity.
Flexible Design
GENESIS Commercial Split Ducted indoor units are designed to support the varied demands of commercial installations, where site layouts, ceiling spaces and service access requirements can differ significantly.
To enhance installation adaptability, the indoor units offer an optional vertical discharge configuration, giving contractors greater flexibility to tailor the system layout to suit project-specific requirements while supporting effective airflow distribution and long-term serviceability.
R32 Leak Detection Sensor
The built-in R32 Leak Detection Sensor
enhances safety by quickly and accurately
detecting refrigerant leaks. Designed for long-
term reliability, it self-monitors for up to 15 years, providing continuous protection and peace of
mind.
Double-Sloped Main Drain Tray
The main drain tray features a clever double- slope design, which greatly improves drainage efficiency and helps prevent water build-up within the unit.The main drain tray features a clever double- slope design, which greatly improves drainage efficiency and helps prevent water build-up within the unit.
Indoor High Static EC Plug Fans
Designed for demanding applications, High Static EC Plug Fans deliver precise airflow control up to 500Pa, offering quieter operation, improved energy efficiency, and greater flexibility for commercial installations.Designed for demanding applications, High Static EC Plug Fans deliver precise airflow control up to 500Pa, offering quieter operation, improved energy efficiency, and greater flexibility for commercial installations.
Outdoor High Static EC Fans
Not only do these high static EC fans offer exceptional efficiency, but they also deliver a quieter performance. They are specifically designed to provide the rated outdoor airflow up to 90Pa.Not only do these high static EC fans offer exceptional efficiency, but they also deliver a quieter performance. They are specifically designed to provide the rated outdoor airflow up to 90Pa.
R32 Inverter Scroll Compressors
R32 inverter scroll compressors deliver precise capacity control to closely match real-time load demands. This results in higher efficiency at part load, more stable temperature control, and reduced energy consumption across a wide range of operating conditions.R32 inverter scroll compressors deliver precise capacity control to closely match real-time load demands. This results in higher efficiency at part load, more stable temperature control, and reduced energy consumption across a wide range of operating conditions.
Condensate Drain
The outdoor unit’s integrated condensate drain ensures efficient removal of excess moisture, helping to prevent water build-up, protect components, and maintain reliable performance in all conditions.
Louvred Grille Guard
Featuring a unique powder-coated louvered grille guard, this product ensures protection against Australia’s toughest conditions. From hailstorms to the relentless heat of the sun, this design is specifically engineered to provide a strong defence against the elements.Featuring a unique powder-coated louvered grille guard, this product ensures protection against Australia’s toughest conditions. From hailstorms to the relentless heat of the sun, this design is specifically engineered to provide a strong defence against the elements.
Hydrophilic Blue Fin Coil Coat
Hydrophilic Blue Fin coating enhances water run-off across the coil, minimising moisture retention and supporting efficient heat exchange. The coating also provides an additional layer of corrosion resistance, helping maintain performance in demanding outdoor environments.Hydrophilic Blue Fin coating enhances water run-off across the coil, minimising moisture retention and supporting efficient heat exchange. The coating also provides an additional layer of corrosion resistance, helping maintain performance in demanding outdoor environments.
Performance
Enhanced Capacity Flexibility
with Tru-Max
GENESIS Commercial Split Ducted systems feature Tru-Max functionality, allowing the system to deliver up to 10% above its rated capacity when operating conditions demand it.
This added capacity flexibility helps the system respond to changing building loads, peak ambient conditions and periods of increased demand. By providing additional performance headroom when required, Tru-Max supports consistent comfort, improved temperature control and reliable operation across a wider range of commercial applications.
Low Ambient Cooling
Reliable, Wide Operating Range
Dry Mode
Enhanced Corrosion Resistance
Quiet Mode
GENESIS includes a Quiet Mode that reduces operating noise during cooling or heating by moderating compressor and outdoor fan speeds. This supports quieter operation without compromising comfort, making it suitable for noise-sensitive commercial and light commercial environments.
Adaptive Defrost Logic
Turbo Mode allows GENESIS to temporarily operate at maximum capacity to quickly achieve the desired temperature. After the set period, the system automatically returns to the original operating settings to maintain steady, efficient operation.
Turbo Mode
Turbo Mode allows GENESIS to temporarily operate at maximum capacity to quickly achieve the desired temperature. After the set period, the system automatically returns to the original operating settings to maintain steady, efficient operation.
Performance beyond Peak Demand.
GENESIS has been engineered with energy efficiency at its core, delivering up to 10% lower power consumption compared to its R410A predecessor.
Designed to perform efficiently across real-world operating conditions, GENESIS places a strong focus on part-load performance. This is especially important in commercial applications, where systems are typically selected to meet peak load requirements but spend much of their operating life running below full capacity.
By maintaining efficient performance at reduced loads, GENESIS helps support lower energy consumption, improved operational efficiency and more cost-effective comfort across commercial buildings.
Energy Efficiency
Variable compressor speed operation helps reduce energy spikes associated with frequent start-up and shutdown, supporting more efficient and stable system operation.
Cost Savings
By adjusting output to match demand, the system uses only the energy required for the load, helping reduce overall energy consumption and ongoing operating costs.
Consistent Comfort
Inverter-driven control supports stable temperature regulation, helping maintain a comfortable indoor environment with reduced temperature variation.
Controls
A Choice of Controllers
Bluetooth Commissioning Tool (BCT)*
* Standard inclusion on 72-96kW models
Variable Fan Technology (VFT)*
* Available as an option, request a quote
Additional Coil Protection*
GENESIS Commercial Split Ducted systems can be specified with additional coil protection for both indoor and outdoor coils, supporting improved durability in demanding commercial environments.
This added protection helps safeguard key heat exchanger components against corrosion and environmental exposure, making it particularly beneficial for projects in coastal, industrial or harsher operating conditions where long-term reliability and asset protection are important considerations.
* Available as an option, request a quote
ActronSelect
Fast, Accurate HVAC Selection Made Easy
Browse our Commercial Packaged Solutions
Variable
- Variable Speed Compressor
- R410A & R32 Refrigerant
- Variable Speed Indoor Fan*
- Multiple Handing Options*
- BMS Option*
Products in Range
Tri-Capacity
- Multi Stage Compressor
- R410A refrigerant
- Variable Speed Indoor Fan*
- Multiple Handing Options
- Economy Cycle Option
- CO2 Sensor Option
Products in Range
Fixed Speed
- Fixed Speed Compressor
- R410A refrigerant
- Variable Speed Indoor Fan*
- Multiple Handing Options*